Stationary storage systems based on Lithium iron phosphate (LiFePO4) are very durable thanks to the chemical properties of their cells and in constant environments. Similar to the genes and individual living conditions which influence a person’s life span, the service life of a battery system is affected by the chemical compound in the cell as well as by external influencing factors such as ambient temperature, depth of discharge or vibration. In this sense, solar batteries based on lithium iron phosphate feature accordingly “robust genes”, since their stable cell chemistry promotes a long service life.

As mentioned above, the ambient temperature of the battery is an important factor which influences the aging of the system. While mobile applications have to withstand severe temperature fluctuations in some cases, photovoltaic storage systems are permanently installed in buildings. Exposure to sub-zero temperatures and temperatures over 40°C causes a gradual capacity loss and a reduction of ampere capacity. Practical experience shows that an optimum operating temperature ranges from 5°C to 30°C. Solar energy storage systems that are usually installed in basement storage rooms are constantly exposed all year round to exactly these temperatures in buildings owned e.g. by solar plant operators.

Another factor that positively affects the durability of solar batteries is the absence of capacity-reducing effects caused by vibration during stationary use. When electric vehicles travel on roads, battery-operated locomotives speed along the tracks and airplanes make bumpy landings, these vibrations leave their mark on the battery systems. The situation is similar for mobile telephones. In an inside pocket of a jacket or in pocketbooks, a cellphone is joggled a bit with every movement. Eventually these impacts and shocks reduce not only the capacity but also shorten the potential service life of these mobile battery systems. In contrast, solar batteries are permanently installed in one location and can infinitely exploit their full potential.

The amount of charge and discharge voltages plays a special role here. To put it simply: high charge and discharge voltages lead to shorter battery life. This voltage is usually specified as the C-rate. C-rates are the factor that specifies the maximum charge and discharge currents of a battery with regard to its capacity. In mobile applications such as electric vehicles, very high rates of up to 20C can occur because vehicles have to accelerate or deal with slopes. In stationary storage systems, rates ranging from 0.1C and 0.5C make it possible to operate the systems for decades and almost completely maintain their capacity.

Another chemical influencing factor is the depth of discharge (DOD) of a system. Lithium ion storage systems clearly outperform the currently dominating lead technology in this regard. Lead batteries usually have a usable depth of discharge of 50 percent, which means that only half of the capacity of these batteries can be used. Lithium battery storage systems achieve distinctly higher values without any negative effects. Depths of discharge of over 70 percent also increase the actually usable storage capacity.

When it comes to efficiency, lithium batteries are clearly superior to lead systems, which achieve efficiency factors of 70 to 80 percent, while competing lithium systems boast factors way above 90 percent. That does not seem much at first glance, but it means that 20 percent less of the previously stored energy is lost in lithium systems in each of the roughly 250 charging processes a year.

In the third part of the blogpost, which will be released on November, 20 2014, I will summarize what service life customers can expect.

I also edited this article for „ees International – The Electrical Energy Storage Magazine“, where it has also been published.