OVERVIEW

Leave a reply
Vanadium Redox Flow Battery in a nutshell

Conventional technologies for the chemical storage of electricity (e.g. electrolyzer, methanation, fuel cells) show a relatively low efficiency. Redox Flow Batteries (RFB), however, show a DC-efficiency of up to 80% – depending on the system and consideration – which is within the range of efficiencies of conventional secondary batteries (lithium-ion, lead or nickel-metal-hydride batteries). In contrast to conventional battery systems in which power and storage capacity are interrelated, Redox Flow Batteries have the ability to scale power and storage capacity independently of each other. Basically the RFB can cover a storage requirement of several hours to a few days.

The structure of a Vanadium Redox Flow Battery (VRFB)
In the simplest case the VRFB contains two pumps, two electrolyte tanks, a stack, a battery management system (BMS); and an inverter when being connected to an AC voltage grid. When connection is made to a DC grid, an appropriate power source and corresponding consumers must be available. First all parts are independently scalable of each other. As a result this also simplifies the maintenance and improves the aging behavior.

Schematic representation of the VRFB

Figure 1: Schematic representation of the VRFB

Stack / power section
The power section of the VRFB consists of an electrical series connection of individual cells, which are hydraulically flowed through in parallel with electrolyte, so that the same conditions prevail in each cell. In technology a stacked structure, similar to a filter press, has established itself. Compared to individual cells high voltage and reduced current can be achieved with this structure.

Electrolyte and pumps
In the electrolyte, the energy is chemically stored in a sulfuric acid vanadium solution. In this case, the volume of solution determines the storage capacity. The theoretical energy density is about 25 watt-hours per liter of electrolyte solution. The electrolyte is conveyed through the stack by pumps.

Battery Management System (BMS)
The BMS controls and monitors the functions of the battery. It regulates the pumps, controls the inverter, and collects the operation data such as state of charge and temperature. These data are recorded and made available for operation monitoring, information and maintenance purposes.

Characteristics and advantages of the VRFB technology
The VRFB technology disposes of a very high system-inherent flexibility and is therefore ideally suited for solving storage topics. Facilities like these have to satisfy two main requirements: First, they must be able to absorb load peaks, in both the generation as well as in consumption (the so-called “peak-shaving”). Second, the system has to store energy during periods of high production and has to release energy in times of low production over a longer period again (“own consumption”).

Flexible and reliable
The VRFB technology is characterized by a high number of cycles and cycle stability. Experiences and aging studies performed by SCHMID, other manufacturers and suppliers show that especially for the stack component a service life of 20,000 cycles or 10 to 12 years can be expected. Due to its chemical properties the service life of the electrolyte is not limited.For Vanadium Redox Flow Batteries deep discharge is possible at all times. In case of need additional amounts of energy can be generated here subject to intermediate restriction of the peak power without causing damage to the capacity or lifetime. Thanks to its short response time the VRFB also stands out from competing technologies. Investigations in the technology centers of SCHMID with stacks in production scale have shown that load steps by 150% of the nominal performance can easily be generated faster than the response time of the control electronics (

Charge state compensation and storage capacity
In conventional systems performance and capacity part are always directly coupled to each other. Over time, inhomogeneities in aging and production lead to a deviation of capacities and charge states of the individual cells. In order to avoid that cells with lowest charge level are deeply discharged or cells with highest charge level are overcharged, and thus causing damage to the installation, complex monitoring and control procedures must be implemented. Still a continuous degradation of the storage capacity cannot be avoided, especially for lithium-ion systems that are intolerant to voltage and deep discharge. This limits the total storage capacity considerably, since the charging or discharging must be stopped when the cells of the lowest capacity are fully charged. Otherwise there is a risk of explosion due to an overload, and often also the risk of thermal chain reaction.

In case of a capacity expansion of conventional systems additional cells or cell groups always need to be installed. This also includes monitoring of the individual cell voltages and a compensation of the charge state. As a result, the complexity of the overall system increases substantially and due to the coupled power section increased costs per kilowatt-hour have to be expected. Contrary to this, the charge state compensation of the individual components of a VRFB within the system is guaranteed since the same electrolyte is homogeneously pumped through the entire system. The overall result is that the storage capacity of a VRFB can be expanded easily and cost-effectively, without having to increase the complexity of the system.

Safety
In direct comparison with other technologies the VRFB impresses through its inherent safety. Since the electrolyte is water-based and does without organic substances or other volatile substances, it is non-flammable and non-explosive. Even the worst and most unlikely fault, the membrane fraction, and hence the direct contact of charged anolyte and catholyte, will not result in an uncontrollable chain reaction. The temperature increase occurring in this process is within the range of 20 – 30°C only. In addition, the stack can be easily replaced here, the battery does not suffer any permanent damage and can continue to operate with a new stack.

The electrolyte is completely recyclable. The recovery process for vanadium is already established by the widespread use of this element in the steel industry. Dealing with sulfuric acid and metal-containing solutions, as they are used in the VRFB, has become established state of the art for many years, taking into account sustainable and ecological criteria.

System costs
The actual unique selling point of the VRFB, however, becomes apparent only at a discharge time of several hours. Figure 2 shows: When the system capacity increases, the system costs for the VRFB decrease faster than for lithium-ion systems.

abb2 en

Figure 2: Arising storage costs, depending on the storage capacity

The storage costs are the acquisition costs of the battery divided by the energy stored during service life of the system (here 10,000 cycles are assumed for both technologies). The storage costs for lithium-ions are derived from two commercially available household storage devices (5kW platform). With a daily discharge of more than 4 hours, the VRFB is already more economical than lithium-ion batteries. This means the longer the duration of VRFB discharge, the more profitable it is compared to the lithium-ion battery.

Summary and outlook
The use of storage batteries in power supply systems will greatly change the conventional generation and transmission of energy. Small to medium sized installations will enable autonomous Smart Grids and a supply from household to city level. In addition, large-scale facilities will ensure efficient cross-linking of local networks. Based on its dynamic behavior (real time charge state monitoring, short response time and short-term high-performance output) the VRFB is perfectly suited to answer complex issues of supply. Therefore, the VRFB can for instance meet the technical requirements of the network services.

Authors: Christian Andreas Fuhrmann, Head of Research & Development for Vanadium Redox Flow Batteries at SCHMID Group & Dr. Christophe Fery, Product Manager at SCHMID Energy Systems GmbH.

Tags: , , , , ,