23 households, 145 kW installed solar power, one central electrical storage system and multiple thermal storage systems: in the Weinsberg pilot project, KACO new energy GmbH shows that it is possible to completely meet energy requirements with solar power. The official grand opening ceremony of the model housing estate took place on 6 June 2014 and was attended by the Baden Württemberg’s environment minister Franz Untersteller. One year later an initial review was made.
Owners of photovoltaic systems, whether private or commercial, typically only cover a small portion of their electricity requirements with solar energy. In the past, for many years the standard practise – promoted by Germany’s EEG (Renewable Energies Act), for example – was that self-generated electricity was sold back to the regional power grid operator. The power drawn from the grid for household consumption also stayed standardised. Of course, these relationships originated during a time when the feed in tariff (FIT) was significantly higher than the costs for consuming electricity from the grid. Since the FIT for newly installed PV systems has sunk to a level much lower than the private consumer price per kilowatt hour, the situation is worth reconsidering again. In light of the rapidly sinking cost of investment in a photovoltaic system – resulting in a acquisition costs of about 10 euro cents per kilowatt hour – it becomes quite clear how solar power is most sensibly used: consumed directly on-site. And, in fact, not only for electrification but also for room and water heating. That’s where the major energy cost drivers are – a fact often overlooked in the din of heated debate over electricity costs. Heating with electricity? Touching on this has been a taboo in a typical environmental discussion, because it’s synonymous with ‘wasting energy’. But only, however, if the focus is on “fossil fuel energy” and “power line losses”. If the electricity is derived from local photovoltaic systems, though, it is considered to be an economically and ecologically perfect source of heat energy.
Self-usage needs management
The concept may seem logical and simple, but the technical implementation requires a great amount of know-how from all building trades involved – and of course a magnitude sufficient to convince the doubters and enthuse interested parties. Thus, KACO new energy – a pioneer in the photovoltaic industry – joined forces with a “seasoned solar” builder and the experts at the Fraunhofer ISE (Institute for Solar Energy systems) to deliver proof of complete renewable energy provision for a newly built housing estate. On the outskirts of the 11,000-resident community of Weinsberg in the German state of Baden Wuerttemberg, a total of 23 residential units were built: six stand-alone houses, three townhouses and two larger, multiple-flat family residences. The “powerplants” generate an output of 145 kilowatts of photovoltaic electricity from a distributed installation on the roofs of the buildings. As one goal of the project was to provide the “greatest possible degree of electrical independence”, the photovoltaic generator was slightly over-dimensioned and maximum use was made of the roof area for installing PV modules.
KACO new energy, responsible for providing energy to the housing estate, approached this with an integrated concept that achieved a high degree of coverage with solar power and consequently the lowest possible feeding in of solar power into the grid: Excess electrical energy coming from the photovoltaic generator which is not needed at the moment is transferred as electricity into an electrochemical storage and – this is new – as heat into thermal storages, available for use at a later time.
Serving as the central unit of the electrical power distribution, an AC-coupled bidirectional battery inverter, which charges and draws electricity from the lithium-ion batteries, which – with a capacity of 150 kWh – serve as a buffer for solar power that is not immediately consumed. Due to its degree of efficiency, and particularly its having the shortest response times, the bidirectional battery inverter ensures that the power supply to a household is uninterrupted, including stable off-grid operation of the entire dwelling in the event that the public distribution grid fails. Solar power which is not immediately in demand by electrical consumers drives a heat pump with 35 kWel output, which in turn feeds a buffer storage unit with a 20,000 litre capacity. It only serves the heating system, and is therefore completely separate from the drinking water system. In addition, 18 decentralised smaller water tanks are heated directly; they are located at the individual buildings to cover the daily demand for hot water.
An energy management system was created for the entire residential complex, which assumes control of all electrical and thermal components. Through the perfect reconciliation of current needs and long-term usage patterns, this energy management system achieves the ideal balance between direct consumption and both the “battery” and “water compartment” storage technologies. This means nothing less than total coverage of the complex’ own consumption. A comprehensive measuring and monitoring system records all of the housing estate’s electrical and thermal energy flows. The regular analysis of this data serves to continually optimise energy management.
Ready for anything
The housing estate is not only integrated in the usual public electricity grid but also in a local heating network, which connects to all buildings. If due to the weather or consumption the electric power supply from the photovoltaic system and storage system is insufficient for the heater, an integrated combined heat and power unit (CHP) with 11 kW electrical output and 27 kW thermal output is put into operation. Because the CHP serves as a “backup”, it only makes a minor contribution towards heating the homes and is thus switched on for less than its required economic operating period. For the cold-weather season, a natural-gas-operated, peak-load condensing boiler with 240 kW output is also available.
Tough learning curve
One of the most important lessons to be learned from such a complex system is certainly just how important and arduous it is to integrate both of the aspects heat and electricity together in a single project with a single goal. Especially when both sides – both the technical planning and the implementing parties – are actively involved and, particularly the latter, have to take on substantially more programming and calibration for heating work than is usually the case for electrical projects. This can lead to “translation errors”; there is an ongoing need for communication in handling the project. An example of this is the familiar problem of Legionella bacteria in the water supply. Depending on how the TWV (German Drinking Water Ordinance) is interpreted, for example, “regular” or “constant” heating of the drinking water is possible to ensure a bacteria-free supply. If the main heat-storage unit is then configured to maintain a “constant 60 °C”, this has an enormous effect on its capability to store solar power.
Getting the communication with and control of the battery block right also proved to be a meticulous task. Take a look at the safety requirements: That a battery operation installation in a residential area must be provided top security goes without saying. However, the constant sampling of all storage parameters with the objective of complete surveillance can overload the system to the point of a standstill. Result: intermittently the battery is unavailable – solar electricity is ‘pushed off’ into the grid.
Along with the system-related quirks, smaller issues with the components occurred –to be detected only after operation had begun. For instance, if they – such as the heat pump – cannot meet the expectations (which requires a new approach) or if they simply don’t “fit the bill” such as the gas pressure monitor that was not apt for the specific gas connection and temporarily brought the entire CHP to a standstill.
As for the status today, it should be noted that: Every similar system will pose new and very individual challenges to the persons responsible for the project; there is no “mould” for casting the most efficient integration of electricity and heat, fed by photovoltaics. A modular software structure for the energy management system (EMS) appears, however, to be an absolute necessity in any case. Particularly in this regard, we acquired a higher level of expertise that bolstered our solid understanding of the subsystems and focus on the potential for reapplying this knowledge in future implementations.
Target and actual values
The modelling for the described layout shows that the decentralised production and storage of solar power plus CHP covers 97% of the electricity demands and around half of the heating demands of the model housing estate. Our simulations show that a 100% coverage of heating requirements is merely a question of the insulation standard applied. In the actual system, major intervention was necessary up to the end of 2014 in order to adjust the interoperation of the components. Now that half a year has already gone by with a nearly rock-steady operating condition: what does the comparison between the forecast for electric power and heat provision and the actual measured values look like? First, it should be pointed out that the specification that 97% of the electricity should be self-generated stems from the model: the maximum to be expected was at the same time the target value. This was not only ambitious but risky, because there was no leeway for any uncertainties. And they, to be perfectly honest, will come up in any case; the more complex a system, the greater the element of surprise.
Referring to the example above: In order to satisfy the German Drinking Water Regulation with certainty, all water tanks were heated to a constant >60 °C. At first glance, continuous heating appears to be “useful” for absorbing as much PV-generated electricity as possible. A look at the thermodynamics, however, clarifies the relationships: the thermal flow between two compartments is driven by the temperature difference, thus a constantly high temperature in the water tank diminishes the inflow of heat and consequently the intrinsic consumption. The previously mentioned limited availability of the central battery block also has an effect on the intrinsic consumption rate. If the battery is inaccessible when the PV generator needs to deliver electricity, then consequently it must be fed into the grid. The self-consumption drops accordingly.
Equally surprising has been the gas consumption to date: according to current projections, it will clearly exceed the determined target volume. The conclusive explanation for comes from the residual moisture in the building structure. Although the dryers had drawn substantial amounts of electricity from the grid (see Fig.: ), the complete “drying period” is significantly longer than one would generally expect. Indeed, up to two years can pass before the temperature and moisture content of an entire building are in line with the ambient environment.
Outlook with confidence
After the temperature control of the individual water tanks has been reset and a periodic anti-Legionella cycle at 70 °C is programmed for the drinking water compartments, the necessary temperature difference is then attained and the capacity of the central storage tank for solar energy will be as planned. Likewise, an optimized battery actuation takes the availability to the calculated level. With these corrective measures, the targeted value of 70% of all electricity being delivered by the PV array will presumably be achieved in the first year of full operation. In addition, based on the current interpretation of the values, the heating requirement should also decline.
In future, the building insulation standard and the installed photovoltaic output will likely be the most important control variables: raising both of them will, of course, entail increased investments (although falling PV prices in particular could provide decisive relief) which for the most part are ecologically sensible, yet these always require an individual calculation as to their economic viability. An essential general condition for the optimum economic relationship between the installed output for own consumption and self-sufficiency is whether there is some sort of FIT and what it looks like.
Altogether, the pilot housing estate in Weinsberg already demonstrates now how, with a decentralised photovoltaic energy supply, the usage of solar power can be optimised to achieve a high degree of energy self-sufficiency and a system concept which is beneficial to the grid can be implemented.
Author: Andreas Schlumberger, Head of Corporate Communications at KACO new energy. This blog entry is based on an article that has been published in ees International – The Electrical Energy Storage Magazine – Issue 03|2015.